π§ IT network
This page lists what the customer's IT department must provide for Fuzz to work: the controller's IP address, the outbound connections to allow towards the Internet, and the exchanges on the local network. It is designed to be passed as is to the site's IT contact. The concepts are explained simply for the installer.
Key points first: Fuzz needs no inbound opening from the Internet. The controller (or the gateway) opens all its connections to the Fuzz servers itself; the Console then uses these connections to reach the site.
β Checklist for the IT department (Edge site)β
- A network socket for the controller, on a network with Internet access.
- A fixed IP address for the controller as soon as there are OCPP charge points on the local network (DHCP reservation on its MAC address, or address entered in the installer menu).
- Outbound traffic allowed to
evproxy.fuzz.energy(address63.179.40.7) on TCP 22. - Outbound traffic allowed to
api.fuzz.energyandauth.fuzz.energy(same address63.179.40.7) on TCP 443. - Outbound traffic allowed to the cloud services (AWS) listed below.
- Working DNS (UDP 53, and TCP 53 if needed).
- NTP time synchronisation (UDP 123 outbound to
*.pool.ntp.org, or an internal NTP server). - On the local network: the controller reaches the Modbus TCP assets (TCP 502 by default) and the charge points reach the controller over OCPP (TCP 8080).
- Fixed IP addresses for the Modbus TCP assets and for those whose web interface you want to open remotely.
π§© A few concepts for the installerβ
- IP address: the address of a device on the network, for example
192.168.1.20. Charge points and Modbus assets must know the controller's address, and vice versa. - DHCP: the network service that hands out IP addresses automatically. Without precautions, a device's address can change at every restart. A DHCP reservation tells the network to always give the same address to a device, recognised by its MAC address (its hardware identifier, printed on the label).
- Port: a number that designates a service on a device (502 for Modbus TCP, 8080 for the controller's OCPP, 443 for secure web, 22 for the Fuzz secure link).
- Outbound / inbound: an outbound connection goes from the site to the Internet (this is the case for all Fuzz connections); an inbound connection would come from the Internet to the site (Fuzz does not need any).
- Firewall: the device that allows or blocks these connections. A stateful firewall, the most common case, automatically lets through the replies to allowed outbound connections; a stateless device must allow them explicitly.
π₯οΈ Controller IP addressβ
The controller connects to the site network through its eth0 port. It must have a fixed IP address as soon as OCPP charge points connect to it over the local network: their OCPP URL contains this address (ws://<controller-ip>:8080/ocpp16/...). Without an OCPP charge point on the local network, an automatically assigned address (DHCP) is enough.
There are two ways to get a fixed address:
- DHCP reservation (recommended): the IT department reserves an address for the MAC address of the controller's eth0 port. This MAC address is printed on the controller's label and on its box; it is also its serial number in the Console.
- Address entered on the controller: the installer sets it up in the controller's installer menu (Network configuration), with the information provided by the IT department: IP address, subnet mask, default gateway, DNS servers. See Installer menu.
The controller's second network port (eth1) is a service port for the installer. See Network connection.
π Outbound connections to Fuzz: domains and ports to allowβ
| Destination | Port | What it is for | When |
|---|---|---|---|
evproxy.fuzz.energy (63.179.40.7) | TCP 22 | Permanent secure link between the controller and Fuzz (Fuzz Secure Link): Console, logs, asset web interfaces, public OCPP URL | Permanently |
api.fuzz.energy, auth.fuzz.energy (63.179.40.7) | TCP 443 (HTTPS) | Controller onboarding and exchanges with the platform | At installation, then in operation |
The name console.fuzz.energy, used by browsers to open the Console, points to the same address 63.179.40.7. A firewall rule by IP address therefore covers all three names.
If the network requires a proxy to get out to the Internet, contact Fuzz (support@fuzz.energy) before the installation.
βοΈ Cloud services (AWS)β
The Edge controller also uses cloud services hosted at AWS, in Europe (Frankfurt region).
In normal operationβ
| Destination | Port |
|---|---|
ab1833q6mlyrv-ats.iot.eu-central-1.amazonaws.com | TCP 8883 |
c9nsxgthwgeph.credentials.iot.eu-central-1.amazonaws.com | TCP 443 |
greengrass-ats.iot.eu-central-1.amazonaws.com | TCP 8443 |
*.s3.amazonaws.com | TCP 443 |
*.s3.eu-central-1.amazonaws.com | TCP 443 |
During installation onlyβ
During the first onboarding, the controller downloads and installs its software. It must then also reach:
| Destination | Port |
|---|---|
iot.eu-central-1.amazonaws.com | TCP 443 |
iam.amazonaws.com | TCP 443 |
sts.eu-central-1.amazonaws.com | TCP 443 |
greengrass.eu-central-1.amazonaws.com | TCP 443 |
d2s8p88vqu9w66.cloudfront.net, awscli.amazonaws.com, apt.corretto.aws | TCP 443 |
github.com | TCP 22 |
| Package repositories of the Debian / Raspberry Pi OS system | TCP 80 and 443 |
If these accesses are blocked, onboarding fails; the installer menu diagnostics and the onboarding logs help find which one. See Putting the controller online.
π€ DNS and time (NTP)β
- DNS: the controller must be able to translate names (
evproxy.fuzz.energy, the AWS addressesβ¦) into IP addresses. It uses the DNS servers given by DHCP, or those entered with the fixed address. Allow outbound DNS requests (UDP 53, and TCP 53 if needed) to these servers. - NTP: the controller needs an accurate time for its secure connections and to timestamp measurements. By default, it uses the public servers
0.debian.pool.ntp.orgto3.debian.pool.ntp.org: allow outbound UDP 123 to*.pool.ntp.org. If the network requires an internal time server, the installer enters it in the installer menu (Set NTP server).
π Exchanges on the local networkβ
The controller communicates with the site's assets over the local network.
| Exchange | Default port | Who opens the connection | IP address |
|---|---|---|---|
| Modbus TCP (meters, inverters, batteries, some charge points) | TCP 502 (configurable per asset) | The controller (Modbus client) to the asset (Modbus server) | The asset must have a fixed IP |
| OCPP 1.6J (charge points, WebSocket) | TCP 8080 on the controller | The charge point to the controller | The charge point does not need a fixed IP; the controller does |
| Web interface of assets (opened remotely from the Console) | TCP 80 (HTTP) or 443 (HTTPS), sometimes another port (8081, 8443β¦) | The controller to the asset | The asset must have a fixed IP |
| Modbus RTU (RS485) | No IP network: RS485 cable to the controller's serial port | β | β |
If the local network is split into several subnets or VLANs, the controller must be able to reach every asset and every charge point must be able to reach the controller.
π Check network access with the installer menuβ
The controller's installer menu offers a network diagnostic (Network diagnostics). It checks, in order:
- that the eth0 port is connected;
- IP access to the Internet (ping to
8.8.8.8); - DNS resolution of
auth.fuzz.energy; - HTTPS access to
auth.fuzz.energy; - access to TCP port 22 of
evproxy.fuzz.energy.
If DNS works but HTTPS does not, the menu suggests checking the customer's proxy or firewall. A ping blocked by the network makes check 2 fail without preventing Fuzz from working if checks 3 to 5 pass.
π See: Installer menu
π Hybrid site: the gatewayβ
On a Hybrid site, a Fuzz gateway replaces the controller on site. It needs:
- outbound Internet access, through Ethernet or its 4G modem (a SIM card with a data plan);
- the same outbound connections as the controller to
evproxy.fuzz.energy(TCP 22) and toapi.fuzz.energy/auth.fuzz.energy(TCP 443), and, during installation, togithub.com(TCP 22) and the system package repositories; - access to the Modbus TCP assets on the local network (fixed IPs), or RS485 wiring for Modbus RTU.
The gateway does not use the AWS cloud services. The OCPP charge points of a Hybrid site do not go through the gateway: see the next section.
π See: The gateway of a Hybrid site
πΆ Charge points connected over the Internet (Hybrid, Cloud, exposed Edge)β
The charge points of a Hybrid or Cloud site, and those of an Edge site whose Internet exposure is enabled, connect to the Fuzz cloud with the public OCPP URL wss://ocpp.fuzz.energy/.... Each charge point needs:
- Internet access (site network or 4G SIM card);
- outbound traffic allowed to
ocpp.fuzz.energy(63.179.40.7) on TCP 443 (secure WebSocket).
No opening is needed on the site network on the controller side: the charge point connects to the Fuzz cloud, which links it to the controller. On an Edge site, exposure is set in Site Parameters > Internet exposure (Allow OCPP connections from the public internet, optionally with a secret key in the URL). On a Hybrid or Cloud site, it is always on; the optional secret key is set in the same place.
π See: Connect a charge point over the Internet
π§© Optional servicesβ
| Service | What to allow |
|---|---|
| Fuzz cloud MQTT broker (assets that publish their measurements over MQTT) | From each asset: TCP 8883 (MQTT over TLS) to mqtt.fuzz.energy. See Fuzz cloud MQTT broker |
| CPO (charging operator that bills the charging sessions) | The controller connects to the CPO as an OCPP 1.6 client (WebSocket); the address and port depend on the CPO (its URL, provided by it). See Connect one or more CPOs |
| Neofleet, Izix and other partners | Depends on the partner; contact support@fuzz.energy. See Partners |
| Console users | From their browser: HTTPS (TCP 443) to console.fuzz.energy and auth.fuzz.energy |