🧩 Asset models (vendor configs)

An asset model, called a vendor config in Fuzz, describes once and for all how Fuzz communicates with a device model: which Modbus registers to read on a meter, how to control a charge point using OCPP, which topics an MQTT asset listens to. Every asset of this model, on every site, uses the same description. It is what you choose in the Model field when you declare an asset in the Console.

📦 What an asset model contains​

ProtocolThe model describes…
Modbus (meters, inverters, batteries, Modbus charge points, fridges, generic assets)The register table: for each measurement (voltage, current per phase, power, energy, state of charge…), the register to read, its data type, the byte order and the scale factor; the registers to write for setpoints (charge point current, inverter or battery power); the default unit ID offered
OCPP (charge points)How to control the current of the charge point (standard OCPP charging profile or a manufacturer-specific parameter), the messages to request from the charge point (measurements, status), the grace period during a disconnection, and how to read measurements when the charge point does not send them in a standard way
MQTT (meters, inverters, batteries)The topics published by the asset, the message format and the MQTT variables to fill in (for example {deviceId})
API (fridges)How to read the measurements in the API response

A well-suited model is essential: with the wrong model, the asset may appear online but give wrong values, or not follow setpoints.


🖥️ Choose the model in the Console​

The Model field appears in the form of each asset, after choosing the Protocol (protocol step, or main step for a meter). The list shows only the models of the chosen asset type and protocol, sorted by name. The names are technical (for example Alfen-SLine, Schneider-PM8000, Huawei-Smartlogger).

CaseWhat the Console offers
OCPP charge pointThe OCPP models, plus Other: if your charge point is not listed, choose Other and enter its brand or model in Model name ("The name or brand of the asset model, e.g. Huawei"). The charge point is then controlled with the standard OCPP behaviour
Modbus, MQTT or API assetOnly existing models. There is no Other option: an asset without a model cannot be saved

For an OCPP charge point, the Offline grace period (seconds) field of the Charge point protocol step takes the value from the model when it is left empty.

Changing the model of an existing asset is done in its form (Edit configuration); the change is sent to the controller like any other change (see When does a change take effect?).


➕ Request a new model from Fuzz​

Creating and editing asset models is not available in the Console for installers and customers: models are created and maintained by Fuzz. The content of Fuzz models cannot be viewed in the Console.

For a device that is not in the list:

  1. Check that it does not exist under another name in the Model field (brand, range).
  2. Send Fuzz support (support@fuzz.energy) or info@fuzz.energy the exact reference of the device (and its firmware version), and its technical documentation:
    • Modbus: the manufacturer's register table (addresses, types, units), and the default unit ID;
    • OCPP: the OCPP documentation of the charge point (configuration parameters, how to limit the current);
    • MQTT: the list of topics and an example message.
  3. Fuzz creates the model and makes it available in the Model field of your sites.

Read a Modbus register table (addresses 40001…)​

Many manufacturers write their registers using the Modicon convention: the first digit gives the table and counting starts at 1. 40001 designates the first holding register (address 0), 40101 the holding register at address 100, 30001 the first input register. Other data sheets give the address directly starting from 0, often in hexadecimal (0x0064 = 100). Send the table to Fuzz as it is, stating the page of the documentation. To test reading a register yourself on site, the Modbus client tool (Configuration > Tools of the site) expects the address starting from 0 in Register start and the table in Table type (see OCPP and Modbus test tools).

A change to a model by Fuzz applies to all assets that use it, on all sites, at the next configuration push to the controllers.

👉 See also: Compatible hardware, Modbus assets, MQTT devices