✅ Compatible hardware
This page is the reference list of hardware validated with Fuzz. Fuzz communicates with assets over OCPP 1.6 JSON (charge points), Modbus TCP, Modbus RTU (meters, inverters, batteries, some charge points) and MQTT (assets that publish their measurements on a broker).
For each validated asset, Fuzz provides a vendor config that describes how to read and control it: this is the vendor config you choose in the Model field of the asset form in the Console (see Vendor configs). The names displayed in this field may differ slightly from the commercial names below.
➕ Add an asset that is not in the list
Adding new hardware requires validation by Fuzz. Contact info@fuzz.energy (or Fuzz support) with the exact reference of the asset and its technical documentation: Modbus register table, OCPP documentation or MQTT message format. Fuzz then creates the corresponding vendor config.
Special case of charge points: an OCPP 1.6 JSON charge point missing from the list can connect to Fuzz by choosing Other in the Model field and entering its name in Model name. It is then controlled with the standard OCPP behaviour; have it validated by Fuzz to benefit from the brand-specific settings. A Modbus or MQTT asset, on the other hand, cannot be declared without a vendor config: ask Fuzz for the vendor config.
Fuzz does not support OCPP 2.0 / 2.0.1 charge points, nor assets that speak neither OCPP 1.6, nor Modbus, nor MQTT.
🔌 Compatible charge points
Charge points connect over OCPP 1.6 JSON (see OCPP configuration of charge points). The charge points marked DC are fast chargers in direct current.
| Brand | Models |
|---|---|
| ALFEN | ProLine, SLine (procedure) |
| ALPITRONIC | HYC1000 (DC) |
| DELTA | Slim 100 (DC) |
| EASEE | Easee charge points, linked from the Easee portal (procedure) |
| EN+ | Argo, Caro, VITA (procedure) |
| ISKRAEMECO | PublicBox, UrbanBox |
| KONKA | ENERGY 200 kW (DC) |
| MENNEKES | Amtron Professional (procedure) |
| PEBLAR | Business |
| PHOENIX CONTACT | CharX |
| POWERDALE | Cluster Powermodule |
| SCHNEIDER | EVLink Smartwallbox (procedure) |
| SMAPPEE | EV Dual, EV Wall, EV Ultra (DC) (procedure) |
| SUNGROW | IDC30E (DC) |
DC charge points are configured like AC charge points, with the site's OCPP URL; there is not yet a per-brand procedure for them in this guide.
☀️ Compatible photovoltaic and batteries
Inverters, datamanagers and batteries connect over Modbus (TCP or RTU) or MQTT depending on the model: see Photovoltaic installations and Batteries. When a datamanager groups several inverters (Huawei Smartlogger, SMA Datamanager), Fuzz queries it directly rather than each inverter. Control (production limitation, charge and discharge) requires the asset to accept a remote setpoint.
| Type | Brand | Models |
|---|---|---|
| Photovoltaic | GOODWE | SMT, MT |
| Photovoltaic | HUAWEI | Smartlogger 3000 |
| Photovoltaic | SINEXCEL | Container |
| Photovoltaic | SMA | Datamanager, Sunny Boy (inverter), Sunny Tripower (inverter) |
| Battery | FOX ESS | G-Max |
| Battery | HUAWEI | Smartlogger + Luna2000 |
| Battery | OCTAVE | One Air |
| Battery | SINEXCEL | Container |
| Battery | VICTRON | Multiplus |
📟 Compatible electricity meters
Meters connect over Modbus (TCP or RTU) or MQTT: see Meters. The site's main meter, placed at the main low voltage switchboard, measures the exchanges with the grid; other meters can measure a secondary switchboard or an asset. A meter missing from this list can be added by Fuzz from its Modbus register table.
| Brand | Models |
|---|---|
| CARLO GAVAZZI | EM24 |
| PHOENIX CONTACT | EEM-MA370, EEM-MA371, EEM-MB370, EEM-MB371, EEM-EM375 |
| SCHNEIDER | PM8000, 32XX series |
| SHELLY | Pro 3EM |
| SIEMENS | PAC 2200 |
| SOCOMEC | Countis E43, E47, E48 |
| VICTRON | Grid Meter |
🔁 Compatible gateways, relays and platforms
| Type | Hardware or service | Use |
|---|---|---|
| Modbus gateway | MetzConnect MR-GW | Converts a Modbus RTU bus (RS485) to Modbus TCP, to connect RTU assets over the Ethernet network |
| Modbus relay | WAVESHARE Modbus POE ETH Relay | Relays controlled over Modbus TCP |
| Platform | EVWay, LastMileSolutions, Monta, Optimile | Charge Point Operators (CPO) to which Fuzz relays the charge points' OCPP traffic (see Connect one or more CPOs) |
| Platform | Neofleet | Fleet management, charging priorities (see Link a site to the Neofleet and Izix partners) |
Other types of assets (generators, compressors, sensors, wind turbines) are not available self-service in the Console: contact Fuzz to discuss them.