5. Connect the assets
This part explains how to connect each asset on the site to Fuzz: what to set on the asset itself (OCPP server address of a charge point, Modbus address of a meter, MQTT broker) and what to enter in the Console. Start by checking that the hardware is in the list of compatible hardware.
Charge points connect using OCPP 1.6 JSON; meters, inverters and batteries using Modbus TCP, Modbus RTU or MQTT. Each asset uses a model supplied by Fuzz. The full description of the Console forms is in Using the Console > Assets.
Compatible hardware
List of hardware compatible with Fuzz - AC and DC charge points, photovoltaic inverters and datamanagers, batteries, electricity meters, Modbus gateways and relays, CPO platforms - and how to get new hardware validated.
Charge points
7 items
Modbus assets (TCP and RTU)
Connect a meter, an inverter, a battery or a charge point using Modbus - difference between Modbus TCP and Modbus RTU, RS485 bus wiring, Console fields (IP Address, Port 502, Unit ID, Read Timeout, Baud rate, Parity), Modbus address, tests and common problems.
Meters
Connect an electricity meter to Fuzz - role of the main meter at the main low voltage switchboard, switchboard and asset meters, Modbus or MQTT, form fields (Meter name, Model, Maximum current), measurement direction, checks and limits without a main meter.
Photovoltaic installations
Connect a photovoltaic installation to Fuzz - compatible inverters and data managers, Modbus or MQTT, what Fuzz measures, production limiting (Set power), curtailment at negative prices, correction factors, inverter switched off at night.
Batteries
Connect a storage battery to Fuzz - compatible models, Modbus or MQTT, what Fuzz measures (state of charge, power) and controls (Set power), state of charge limits, maximum currents, control strategies, checks.
Fridges and generic Modbus assets
Connect a fridge (cooling unit, cold room) using Modbus or API, and a generic Modbus asset - Console fields, model to request from Fuzz, what Fuzz does with it (measurements, alerts), limits and asset types not available.
MQTT devices
Connect a meter, a photovoltaic installation or a battery that publishes its measurements using MQTT - choosing the broker (Fuzz Local MQTT broker on Edge, Fuzz Cloud MQTT broker, other broker), connection credentials shown in the Console, MQTT variables, checks and common problems.
Asset models (vendor configs)
What an asset model (vendor config) is in Fuzz, what it contains for an OCPP charge point, a Modbus or MQTT asset, where to choose it in the Console (Model field, Other and Model name), and how to request a new model from Fuzz.
Open the web interface of an asset remotely
Open from the Fuzz Console the local web page of a charge point, an inverter, a meter or a battery, without a VPN or opening a port - Console step of the form (Protocol, Hostname / IP address, Port, advanced settings), Console tab and Open Secure Tunnel button, charge point case, limits and troubleshooting.